Home >  OEM/ODM > 데이터 센터 산업 > ups> 온라인 무변압기형 UPS> HIP3300 (10-80kVA)
HIP3300
10-80kVA
 
HIP3300 series UPS is developed as a high frequency large capacity tower UPS which adopting similar modular design , excellent performance parameters, more higher efficiency, more reliable, maily used in medium and large data center, bank/security settlement center, dispatching center, control center, management center fields and so on.
General Features

● DSP-controlled technology

● Parallel redundancy up to 4 units

● Wide input voltage and frequency range

● Easy-to-operate LCD display

● High power density up to 500kVA for space saving

● High input power factor and low input distortion

● Output power factor at 0.8(0.9 optional)

● ECO mode for energy saving

● Common or separate battery

● Programmable battery voltage from ±192Vdc to±240Vdc

● Intelligent charge modes with smart charge current adjustment

● Megatec/ModBus protocol supported

● Powerful charger built in

● Versatile communication interfaces provided for different applications

● Superior overload capability

● Programmable control and monitoring software

Technical Specification
MODEL HIP3301
S/H
HIP33015
S/H
HIP3302
S/H
HIP3303
S/H
HIP3304
H
HIP3306
H
HIP3308
H
Capacity
(VA/Watts)
10k / 8k 15k / 12k 20k / 16k 30k / 24k 40k / 32k 60k / 48k 80k / 64k
INPUT
Nominal voltage 380/400/415Vac(3Ph+N+PE)
Operating voltage range 208~478Vac for half load; 305~478Vac for full load 
Operating frequency range 40~70Hz
Power factor ≥0.99
Harmonic distortion(THDi) 2%(100% non-linear load)
Bypass voltage range 380Vac Max.voltage: +25%(optional +10%,+15%,+20% )
400Vac Max.voltage: +20% (optional +10%,+15%)
415Vac Max.voltage: +15% (optional +10%)
Min.voltage: -45% (optional -20%,-30%)
Bypass frequency range  Frequency synchronize tracing range:±10%
Generator access Support
OUTPUT
Rated voltage 380/400/415Vac(3Ph+N+PE)
Power factor 0.8/0.9(Customized)
Voltage regulation ±1%
Frequency Line mode ±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)
Bat. mode (50/60±0.2%)Hz
Crest factor 3:1
Harmonic
distortion (THDv)
≤2% with linear load
≤5% with non-linear load  
Efficiency 94.50% 95.00%
BATTERY
Battery voltage Standard unit: ±216Vdc;   Long run unit optional voltage: ±192 / ±204 / ±216 / ±228 / ±240Vdc
Charging current(A)
(Charging current can be
 set according to battery
 capacity installed)
5.7A (Max./Standard unit)
6.0A (Max./Long run unit)
12A (Max.) 18A (Max.)
SYSTEM FEATURES
Transfer time Utility to battery:0ms; Utility to bypass:0ms
Overload Line mode Load≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% turn to bypass mode immediately
Bat. mode Load≤110%: last 10min,≤125%: last 1min,≤150%: last 5S,≥150% shut down UPS immediately
Short circuit Hold whole system
Overheat Line mode: Switch to bypass; Backup mode: Shut down UPS immediately
Low battery voltage Alarm and switch off
Self-diagnostic Upon power on and software control 
EPO (optional) Shut down UPS immediately
Battery  Advanced battery management 
Noise suppression Complies with EN62040-2
Audible & Visual Line failure, Battery low, Overload, System fault
Status LED &
LCD display
Line mode, Bypass mode, Battery low, Battery bad, Overload & UPS fault
Reading on the
LCD display
Input voltage, Input frequency, Output voltage, Output frequency, Load percentage,
Battery voltage & Inner temperature
Communication
 interface
RS232,RS485,Parallel,Intelligent slot,Relay card(optional),SNMP card(optional)
ENVIRONMENT
Operating
 temperature
0~40℃
Storage
 temperature
-25~55℃(No battery)
Humidity range 0~95% (Non-condensing)
Altitude <1500m. When >1500m, derating power for use
Noise level <55dB
PHYSICAL
Dimension
 D×W×H (mm)
780×600×1200
Net weight (kg) S:598
H:129
S:600
H:131
S:602
H:133
S:603
H:134
170 172 199
STANDARDS
Safety  IEC/EN62040-1,IEC/EN60950-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8